Advanced CANDU reactor

From Infogalactic: the planetary knowledge core
(Redirected from Advanced CANDU Reactor)
Jump to: navigation, search

Lua error in package.lua at line 80: module 'strict' not found. The advanced CANDU reactor (ACR) is a Generation III+ nuclear reactor design and is a further development of existing CANDU reactors designed by Atomic Energy of Canada Limited. The ACR is a light-water-cooled reactor that incorporates features of both pressurised heavy water reactors (PHWR) and advanced pressurized water reactors (APWR) technologies. It uses a similar design concept to the steam-generating heavy water reactor (SGHWR).

The design uses low enriched uranium (LEU) fuel, ordinary (light) water coolant, and a separate heavy water moderator. The reactivity regulating and safety devices are located within the low pressure moderator. The ACR also incorporates characteristics of the CANDU design, including on-power refueling with the CANFLEX fuel; a long prompt neutron lifetime; small reactivity holdup; two fast, totally independent, dedicated safety shutdown systems; and an emergency core cooling system (although all generation 2, 3, and 3+ designs have this feature). The compact reactor core reduces core size by half for the same power output over the older design.

The fuel bundle is a variant of the 43-element CANFLEX design (CANFLEX-ACR). The use of LEU fuel with a neutron absorbing centre element allows the reduction of coolant void reactivity coefficient to a nominally small, negative value. It also results in higher burnup operation than traditional CANDU designs.

The current size for the ACR-1000 is approximately 1200MWe."[1]

The reactors are intended for use in nuclear power plants to produce nuclear power from nuclear fuel.

Safety systems

The ACR-1000 design currently calls for a variety of safety systems, most of which are evolutionary derivatives of the systems utilized on the CANDU 6 reactor design. Each ACR requires both SDS1 & SDS2 to be online and fully operational before they will operate at any power level.[2]

Safety Shutdown System 1 (SDS1): SDS1 is designed to rapidly and automatically terminate reactor operation. Neutron-absorbing rods (control rods that shut down the nuclear chain reaction) are stored inside isolated channels located directly above the reactor vessel (calandria) and are controlled via a triple-channel logic circuit. When any 2 of the 3 circuit paths are activated (due to sensing the need for emergency reactor trip), the direct current-controlled clutches that keep each control-rod in the storage position are de-energized. The result is that each control-rod is inserted into the calandria, and the reactor heat output is reduced by 90% within 2 seconds.

Safety Shutdown System 2 (SDS2): SDS2 is also designed to rapidly and automatically terminate reactor operation. Gadolinium nitrate (GdNO3) solution, a neutron-absorbing liquid that shuts down the nuclear chain reaction, is stored inside channels that feed into horizontal nozzle assemblies. Each nozzle has an electronically controlled valve, all of which are controlled via a triple-channel logic circuit. When any 2 of the 3 circuit paths are activated (due to sensing the need for emergency reactor trip), each of these valves are opened and GdNO3 solution is injected through the nozzles to mix with the heavy-water moderator liquid in the reactor vessel (calandria). The result is that the reactor heat output is reduced by 90% within 2 seconds.

Reserve water system (RWS): The RWS consists of a water tank located at a high elevation within the reactor building. This provides water for use in cooling an ACR that has suffered a loss of coolant accident (LOCA). The RWS can also provide emergency water (via gravity-feed) to the steam generators, moderator system, shield cooling system or the heat transport system of any ACR.

Emergency power supply system (EPS): The EPS system is designed to provide each ACR unit with the required electrical power needed to perform all safety functions under both operating & accident conditions. It contains seismically qualified, redundant standby generators, batteries and distribution switchgear.

Cooling water system (CWS): The CWS provides all necessary light water (H2O) required to perform all safety system-related functions under both operating & accident conditions. All safety-related portions of the system are seismically qualified and contain redundant divisions.[citation needed]

Operational cost

The ACR has a planned lifetime capacity factor of greater than 93%. This is achieved by a three year planned outage frequency, with a 21-day planned outage duration and 1.5% per year forced outage. Quadrant separation allows flexibility for on-line maintenance and outage management. A high degree of safety system testing automation also reduces cost.

Prospects

The ACR-1000 has been submitted as part of Ontario's request for proposal (RFP).

Bruce Power, which has acquired Alberta Energy, considered it in 2007 for deployment in Western Canada, both for power generation, or for steam generation (used in processing oil sands). In 2011, Bruce Power decided not to move forward with this project.[3]

The province of New Brunswick has accepted a proposal for a feasibility study for an ACR-1000 at Point Lepreau.

AECL was marketing the ACR-1000 as part of the UK's Generic Design Process but pulled out in April 2008. CEO Hugh MacDiarmid is quoted as stating, "We believe very strongly that our best course of action to ensure the ACR-1000 is successful in the global market place is to focus first and foremost on establishing it here at home."[4]

See also

References

  1. CANDU Reactors – ACR-1000
  2. CANDU 6 – Safety Systems – Special Safety Systems
  3. Lua error in package.lua at line 80: module 'strict' not found.
  4. Canada's AECL pulls out of UK nuclear reactor study – International Herald Tribune

External links